Leak Detection

Saving costs without compromising server availability

Comprehensive control over all relevant factors is vital to achieve optimal performance and efficiency in a data center. STULZ contributes to this goal by providing the CFD (Computational Fluid Dynamics) service for data centers, using its unique fluid dynamics expertise at the product level to make the CFD simulation more accurate at the application level.

The CFD simulations assist in the analysis, design, and optimization of data centers, resulting in reduced PUE (Power Usage Effectiveness) values, decreased annual energy costs, minimized carbon footprint, and lower yearly investment expenditure.

Common leak sources in data centres

  • Cooling Equipment

    Leaks from condensation, cooling coils connection within CRAC, CRAH, FWU and CDU units.
  • Chilled Water & Refrigerant Piping

    Vulnerable at joints, valves, and fittings due to pressure fatigue, corrosion or pipe sweating.
  • Server Racks with Liquid Cooling

    High risk around quick-disconnect couplings, manifold connections and cooling plates.
  • Sprinkler & Overhead Piping

    Fire suppression systems present risk from accidental activation, corrosion or joint leaks.
  • Plumbing & Condensate Lines

    Condensate drain lines can block or overflow, causing spillage. General plumbing faults are commonly overlooked.
  • Foundation & Floor Seepage

    Groundwater can infiltrate through foundation walls or floor slabs, especially in basement-level facilities.
  • Battery & UPS Rooms

    Flooded-cell batteries can release battery acid or electrolyte fluid during overcharge or failure
  • Diesel Generator Areas

    Fuel storage and generator systems introduce risk from leaks at tank connections, fuel lines and overflow points.

Application Areas

CFD can be used at any stage of the data center life-cycle ― from design all the way through to operations. Acquire reliable predictions of the impact on a data center's resilience, physical capacity, and cooling efficiency.

 

 

 

 

 

 

 

 

STULZ CFD Analysis

Planning reliability

By using CFD simulations, it is possible to design data centers more efficiently and create a buffer zone to test planned measures before implementing them in the actual facility.

  • Save resources and costs by simulating the physical data center layout and parameter before implementation.
  • Develop resilient cooling and power failure strategies for high reliability.
  • Explore innovative cooling concepts and techniques, or simplify complex control systems through modeling.
  • Evaluate vendor equipment to choose the best fit for your facility.
  • Run what-if scenarios to test different possibilities and outcomes.
  • Gain a thorough understanding of temperature distribution and proactively prevent hot spots.
  • Model and analyze various aspects of the entire cooling system, including adiabatic cooling, Free Cooling, external environment, and power network.

Optimizing the operation

Technologies change throughout their lifecycle. As your business grows, it is important take advantage of new technologies in the data center. CFD simulations help to understand your cooling infrastructure in detail enabling you to improve efficiency to reduce costs and increase reliability.

  • Test the availability, capacity, and efficiency of your infrastructure.
  • Investigate external factors on the white space and determine their impact.
  • Determine the optimal layout for your new IT deployments in advance of installation.
  • Run failure scenarios to test the resilience of your system.
  • Identify and prevent hot spots through modeling
  • The various aspects of the cooling system, including adiabatic cooling, Free Cooling, external factors and the power grid, are modelled and analyzed.