Leak Detection System
Where liquid flows, detection follows
As data centres are commonly shifting from air-based to direct-to-chip and immersion cooling technologies, the volume of liquid circulating through the facility is growing substantially. Unlike an immediately detectable power failure, a water leak can go undetected for critical minutes, spreading beneath raised floors, inside cable trays, and the racks before any visible sign appears at the surface. Leak Detection systems provide continuous, facility-wide monitoring. The moment liquid contacts the sensing cable, the controller pinpoints the exact location — accurate to within one metre — triggers an alarm, and transmits the event to BMS, DCIM, or facility management platforms for immediate response.
Product Overview
Most important benefits
- Detect leaks in less than 10 seconds — before damage escalates
- Continuous facility-wide monitoring across all risk zones
- Seamless integration with Modbus / BACnet / SNMP protocols
Most important features
- Fail-safe loopback monitoring for continuous verification
- No cable replacement needed after a leak event
- Certified and UL / CE / RoHS compliant
Most important technical data
- Precise leak location to ±1 metre
- Cables for different fluid types (Hydrocarbons, water, acid, PG 25)
- Scalability from one unit to one building
- Uninterruptible monitoring: Fail-Safe loopback monitoring for continuous verification.
- Reduced downtime risk: Early detection prevents costly outages and equipment failures.
- Faster response: Immediate alerts enable quick isolation and mitigation.
- Asset protection: Safeguard high-value infrastructure on rack, equipment, piping and facility levels.
- Best practices: Support operational excellence and compliance standards.
- Design support: Detailed system design, cable routing layouts, and integration planning tailored to your facility requirements.
- Detect leaks within 10 seconds of liquid contact
- Continuous facility-wide monitoring across all risk zones
- No sensing cable replacement needed after a leak
- Adjustable leak sensitivity per zone
- Cable flexibility for hard-to-access spaces
- Higher accuracy to reduce false alarms
- Seamless integration with BMS, DCIM, and facility management platforms
| Detection speed | Less than 10 seconds from liquid contact |
| Location accuracy | ±1 metre along sensing cable |
| Sensor module capacity | Up to 100 modules per supervising panel |
| Sensing cable types | Water, acid, hydrocarbons, PG 25 |
| Alarm outputs | Audible, visual, dry-contact |
| Integration protocols | BMS, DCIM, facility management platforms |
| Cable replacement | Not required — cable dries and returns to service |
| Fail-safe | Loop Back technology detects leaks even with a broken cable |
| Scalability | Single unit to full building coverage |
Need more information?
All details about Leak Detection System
The risk is real
The consequences of an undetected leak extend far beyond wet floors:
- Electrical hazards and potential fire risk
- Damage to IT infrastructure and critical hardware
- Unplanned downtime and service disruption
- Significant recovery and remediation costs
- Reputational harm and loss of customer trust
- Water damage to building fabric and substructures
- Health, safety, and regulatory compliance exposure
In many cases, leaks begin as minor drips undetectable by routine inspection and escalate rapidly. By the time they are discovered, significant damage may already have occurred, resulting in financial and reputational consequences.
How the system works
Leak Detection systems use a continuous sensing cable that runs along the floor, under raised tiles, or adjacent to pipework. The moment liquid makes contact with the cable, the controller pinpoints the exact location of the leak, accurate to within one metre, triggers the alarm and sends the location data and event to the integrated system for further actions. The system is built around four integrated functions, forming a constant protection layer across every area of the facility.
Solution components at a glance
The leak detection systems are modular and scalable. The requirements may vary significantly depending on facility layout, hydraulic conditions, and existing infrastructure. We offer solutions for your individual requirements — our teams will work with you to assess your site and implement the right solution.
Coverage across the facility
STULZ ecosystem advantage
- APAC-wide coverage — Our regional network ensures consistent support across Asia-Pacific markets, with local expertise in every key territory
- Local design support — Detailed system design, cable routing layouts, and integration planning tailored to your specific facility requirements.
- Regional service network — Trained technicians, rapid spare parts availability, and fast support ensure minimal downtime and maximum system reliability.
- Seamless integration — Integrate directly with STULZ controllers, BMS platforms, and DCIM systems for unified facility management.